QUALITY AND DOCUMENTS

Architects, design offices and public venues often ask us for supporting documents. Here we list every available document and its exact scope: which product, which standard, which result. What has not been tested is also stated.

Reaction to fire

  • CANOPY lichen: classified B-s1,d0 under European standard EN 13501-1. LNE classification report no. P235111 of 17/10/2023, valid until 17/10/2028.
  • CANOPY lichen (US market): tested to ASTM E84, Class A (flame spread 0, smoke 0), Govmark report 3-21212-0-DU (2017), lichen on aluminium panels fixed to gypsum board.
  • Flat, long, ball, fern, rock and hair mosses: M1 result in screening tests under French standard NF P 92-501 (2021). These are screening tests, not an official classification report.
  • Mood moss: no reaction-to-fire test.
  • Fire-retardant artificial plants: fire-retardant treatment as per the manufacturer's documentation, available on request.

Acoustics

  • Lichen panels: absorption coefficient NRC 0.30 under ASTM C423 (Intertek report, 2017). This report describes a measured performance; it is not a product certification.

Product safety

  • Safety data sheets (REACH) for our mosses and lichens, European and US versions (06/10/2023).
  • Official inspection: our CANOPY site in Castries was inspected by the French authorities (DRAAF Occitanie, 2023) for export phytosanitary certification.

Trademarks

  • SECONDFLOR and CANOPY are European Union trademarks registered by MEAMEA (EUIPO).

To receive a document, contact us with the product reference.